Power Transmission
Control and Protection System - 400kV Electrical Substation
Control and Protection Cubicle (400kV)
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: Bay Controller.
Bay Protection Cubicle (400kV)
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: SIPROTEC 87L, 87BB.
OHL Protection Cubicle (400kV)
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: SIPROTEC 87L, 21.
Teleprotection Cubicle
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: SICAM A8000
TRAFO Protection Cubicle (400/110kV)
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: SIPROTEC 87T.
Control and Protection System - 220kV Electric Station
Control and Protection Cubicle
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: SIPROTEC 21
LCC GIS 220kV MASURA
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 60204-1.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
LCC GIS 220kV OHL
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 60204-1.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
LCC GIS 220kV AT
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 60204-1.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
LCC GIS 220kV CTV
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 60204-1.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Control and Protection System - 110kV Electric Station
OHL Protection and Control Cubicle (110kV)
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: SIPROTEC 87L, 21.
Bay Protection Cubicle 110kV
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: SIPROTEC 87L, 87BB.
TRAFO Protection and Control Cubicle (110/20kV)
IEC Design Standard: IEC 61439-1, IEC 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: SIPROTEC 87T.
SCADA System, General Installations
SCADA Cubicle
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: SICAM A8000, RACK PC, Ethernet switch, etc.
SERVER Cubicle
Design Standard: IEC 61439-1, IEC 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: SICAM A8000, RACK PC, Ethernet switch, etc.
Remote Terminal Unit Cubicle
Design Standard: IEC 61439-1, 61439-2 and IEC 61850.
Enclosure type: Metallic, compliant with IEC 61439-1.
Components: CE-marked, compliant with (LVD) (2014/35/EU).
Automation: SICAM A8000.